Connecting the water supply
All kitchens need water.
from the well a pex hose has been routed under the cabin, this hole in the floor was too much work to relocate, thus as for the microwave oven in the corner cabinet, the kitchen has been modeled around this "feature".
No pressure, no water.
-20230514
Previous setup got too cold for survival, the hydrophore cracked and fell apart, new one is needed.
For the new setup I will stack the components in the following order:
* Hydrophore
* outlet to houses
* inlet from pump in well
* quick drain valve -lowest point.
All will be placed on the wall to allow for easy access and the possibility to drain the entire system by opening the valve.

Previous pressure switch connections.
-20230521
All mounted to wall, time to test.
It was quite evident it did not build pressure. tool a walk across the yard and looked for leaks.
found a broken connection that needed mending.
Pressure is building and all seems ok.
Setting up the new pipes
-20241012
Since hot water does not enter the house from the well a water heater is needed.
a sammelr one, about 10l is better than nothing, most likelt can be upgraded if need arises.
I want it hidden away, therefore placeing it in a cabinet above the fridge.
Not tightenning of any connections yet since mockup is still in progress.
Wall mounts are not final, cabinets will be installed with the pipes inside.
-20241023
A standoff is added to the wall, this will also be used to mount outlet to fridge.
Also added is a break out pipe to the heater feed line. thiss can now be used to pump compressed air into the pipes to help empty the water from the heater.

Standoffs testmounted on support.
Measurements are taken and the basin cabinet gets a hole cut
for the drain and inlet to house.
-20241102
3D printed standoff is added to secure the valve

Clamp to be printed.
-20241104

Cabinet in place just to check bend.
Forgot to take a picture of the bends underneath.
-20241107
Planning to use a diy leak tester, just to avoid getting water averywhere. Sourced a few components and assembled this contraption:

Gauge, schrader valve..
-20241108
Planning the setup for pressure safety valve and inlet shutoff.
More suitable location for the safety valve is in the basin cabinet.
the hose can be routed directly to drain.
Additionally, house inlet can be shut off for maintenace.
Winter has arrived, no more pipeworks for this year.
-20250420
Time to add heater to cabinet.
cardboard template to check clearance

Perfectly sized for 600mm cabinet.
Started marking where to vut the inlet pipes for T connector.
decided to wait untel countertops have been cut into place.
The pipes where bent and mounts added to wall.
-20250421
To get the level correct-ish, modifications and custom made standoffs had to be made for all cabinets.
Marking pipes before cutting.
-20250524
Setting water protection under fridge and inside water heater cabinet.
This is a requirement according to the
'Housing Authority'.

Bending and adjusting to fit it in.

Around tubes some putty.
-20250525
Faucet can now be dropped into place and threaded with tools that were
in the same packaging.
As for fridge and heater, inside the sink cabinet a water barrier is placed.

Marking where holes need to be cut.
-20250531
Time to install basin drain pipes.
While assembly was ongoing, first casualty occured.
pipe broke, possibly due to indoor temperature being wery low.

Overflow channel connection broken.

Seal putty to the rescue
Assembly of components was very easy.
Directed all pipes to th right, gives room for ev. trashcan and other stuff.
Additionally, draining the waterlock before freezing temparature is
now easily accessible.

Directing the flow to the right

Final flex tubing cut to size.
Air test completed successfully, leaving the pressure on,
returning in a few hours to see if it still is airtight.
The system was airtight, no preassure lost.
Starting the water pump and then open the inlet valve.
the water heater got filled nicely and the faucet gurgled a bit until some water came out.
.
Suddenly, no water! no matter what was done with the valves, nothing came out of the fsucet, hot nor cold.
For some reason the overpressure valve worked fine...
Perfectly timed phonecall from a friend whiel messing with valves,
seems he recognized the issue, remove faucet aerator -most likely 4 years of not being connected has consequences....
Cleaned the components, in the house, in the guest house and the bathroom, all had a lot of dirt in them. -water flows again.
Since no leaks of water nor air can be seen I'm turning off the pump.
returning in a few days to see if the
hydrophore does its job and no leaks
can be detected
.
-20260322
During the winter, a pipe connection burst open due to ice.
It was rather difficult to empty the water when the house was prepped for winter.
Need to rethink the inlet for cold water, seems like the overpressure
valve is blocking the system, it also seems to be broken.

Not functional.
Cleaned up the mess and disconnected all pipes, will need to adress this during spring.
-20260425
Some assorted couplings and ball valves were procured.
A new pressure relief valve
as well.








The new setup takes the check valve into account and the cold water
is now via T connection guided to water faucet and to the heater.

Mockup of new setup.
I will add a T fitting to the warm water "lowest" point and enable it to be emptied via a hose under the kitchen counter.
First the old 90° connections need to be cleaned and redone.

Old fittings removed.

Cut to allow for new 90° fitting.
To fit the new setup for inlet, copper pipe needs to be cut a few
millimeters.

How much to cut?.
Hoses and valves were added, including endcaps

Cold water T fitting.
Next step is to add new water protection to the underside of the fittings.
TBC